Menu
play vidio

50hz 22kw ac drive 3 phase frequency inverter VFD

50hz 22kw ac drive 3 phase frequency inverter VFD

Wuxi Mochuan Drives Technology Co.,Ltd

128 views

Uploaded on 1 year ago

Max Frequency: V/F control 0-3200hz
Carrier Frequency: 0.5Khz-16Khz(zhe carrier frequency can be adjusted automatically according to the load characteristic)
Input frequency Resolution: Digital setting: 0.01Hz;analog setting: MAX frequency x0.025%
Control Way: V/F control
Starting Torque: 0.5Hz/150%(SVD);0Hz/180%(FVC)
Speed Range: 1:100(SVC);1:1000(FVC)
Torque Control Precision: ±5%(FVC)
Overload Capacity: 150% rated current 60s;180% tated current 3s.
Torque Increase: Automatic torque enhancenment; anual torque improvement 0.1%-30%
V/F Curve: three way; linear;multipoint; N-power V/F curve(1.2-power,1.4-power,1.8-power,2.0-power)
V/F Separate: 2 way:full separation,semi-detached
Acceleration Deceleration Curve: Linear or S-curve plus detakeration.Four acceleration
and the range decelertion time 0.0-6500.0s
DC Brake: DC brake frequency:0.00Hz-50.00Hz
Brake time: 0.0s-36.0s
Braking action current value:0.0%-100.0%
Inching Control: Inching frequency range:0.00Hz-50.00Hz
Inching deceleration time: 0.0s-6500.0stimple PLC,Multistage: Through built-in PLC or control terminal to realize Max 16 speed running
Built-PID: To realize the process control closed-loop control system
Automatic Voltage Regulation(A/R): When the grid voltage changes,to keep output constant voltage
Overpressure Loss Rate Control: Automatic limit of current during operation to prevent overcurrent
overvoltage to stop
Fast Current Limiting Funcation: Maximum reduce overcurrent failure to protect the frequency converter normal run
Torque Limitation and Control: Feature of evcavator,automatic limiation of torque during operation to prevent frequency overcurrent to stop; Closed-loop vector mode can realize torque control.
Outstanding Performance: With high performance current vector control technical to realize and control asynchronous and synchronous motor.
Instanteous Stop Constantly: In the instantaneous power fail,through load to freedback energy to make up the voltage reduce,to maintance frequency converter frequency appear overcurrent fault.
Rapid Current Limiting: To avoid frequency converter frequency converter frequency appear overcurrent fault.
Virtual I/O: Five groups of viriitual DIDO to realize simple logic control.
Timing Control: Timing control function: setting range time 0.0Min-6500.0Min.
Multimotor Switching: Four group motor parameters, can realize four motor to switch control.
Using Place: Indoor, not exposed to direct sunlight, dust, corrosive gas, flammable gas, fog, water, vapor, water or salt.
Altitude: lower 1000m
Environment Temperature -10C- -40C(environment temperature in 40C-50C, please derating use.
Humidity <95% RH, no water condense
Vibration <5.9m/s²(0.6g)
Store Humidity -20C- +60C