0.6/1kV Cu/XLPE/PVC Power Cable(xlpe Insulated Cable, Electric Cable)

  Posting Date : Oct 11, 2008 GMT
Click to enlarge image
Company: GuangXi GuiGang QunXing Cable Co., Ltd
Membership: Free Member since Jan 19, 2008
Coutnry/Regioin: ChinaChina
Address: Western Industrial Park Gangbei District, GuiGang, Guangxi, China 537100
Contact: Mr. Jiangjian
Phone: 86-775-4272-238
Fax: 86-775-4272-207
Tags: power cable
Online Postings: More 5 Trade Leads
add to cart Bookmark and Share

Features Specifications: 0.6/1kV Cu/XLPE/PVC Power Cable(xlpe insulated cable,electric cable)
Insulation Material: XLPE Type: Low Voltage Conductor Material: Copper
Jacket: PVC


0.6/1kV Cu Conductor XLPE Insulated PVC Sheathed Power Cable

Standard :

It is manufacture under GB/T12706-2002 standard(The same as IEC60502).



Application:

It is used to transmit and distribute power in power transmission and distribution system of 1kV. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.



Using features:

1. Rated voltage: Uo/U: 0.6/1kV

2. No. of core: Single-core, Two-core, Three-core, Four-core, Five-core,Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC.

4. D.C. resistance of the conductor complies with the stipulations of GB/T3956-1997.

5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

6. The cable is laid without horizontal drop limit.

7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.




(cable, power cable, power wire, electric cable, electrical cable, xlpe insulated cable, xlpe insulated power cable, pvc cable, pvc power cable, xlpe cable, xlpe power cable, pvc sheathed cable, pvc sheathed power cable,insulated cable)

Optional Information
- HS Code : 8544 Insulated Wire, Cable and Other Insulated Electric Conductors

Contact Information
Mr. Jiangjian
 
Company : GuangXi GuiGang QunXing Cable Co., Ltd
Address : Western Industrial Park Gangbei District, GuiGang, Guangxi, China
Zip/Postal : 537100
Telephone : 86-775-4272-238
Fax : 86-775-4272-207

Email this page Bookmark and Share