infusion syringe Pump (SK-500II)

Payment
TT in advacne ,LC
Delivery
7 working days after confirm the payment
Origin
Shenzhen,China
Packaging
Standard , Neutral
Inspection
QC or third party
Samples
Charge
Remarks
We have our R& D Dep. and Factory, also OEM, ODM, and customers’ service we could do for you.

Product Description

1. Three kinds of mode: Rate Mode, Time Mode, Body Weight Mode.

2. User-friendly, easy to operate, safe and convenient. English indicators, easy to identify.

3. Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml.

4. Unique injection supervision system ensures the safe injection and reduces the nurse`s workload.

5. Excellent injection operation. The accuracy will be ensured even at small-volume injection.

6. Double CPU system makes the process of injection safer and more reliable.

7. Precision step motor. There is no pulsating wave even during low-rate injection.

8. Accurate and sensitive pressure sensor detects occlusion pressure accuracy.

9. Alarm is given when there is malfunction or operation error, and the machine stops running automatically.

10. KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h.

11. Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume.

12. Injection time, dose, solution can be checked during the process of injection.

Product Feature

1.Three kinds of infusion mode: Rate mode, Time mod and Body Weight Mode.

2.Suitable for any standard syringes of 5ml, 10ml, 20ml, 30ml, 50 ml.

3.Selectable KVO rate, Bolus and higher rate than SK-500I.

3.Manual system design for LCD.

Product Specification / Models

Dimension: 288*130*122mm Weight: <3.0kg

Power supply: 50/60Hz AC100V~240V

Displayed information:

Flow rate; Accumulated injection volume; Volume limit; Syringe size; Pressure value; Syringe specification; Battery capacity; Unit of medical dosage; AC power indicator; Bed No.

Fuse: 220V2A*2, 12V2A*2

Maximum power consumption: 25VA, 5h after being recharged

Injection increment: 0.1ml

Accumulated injection volume: 0~9999.9ml

Injection accuracy: +/-3%

Alarm function ( All alarms can be transmitted to and displayed on the infusion supervision system at the nurse`s station ):

OVER / NEAR Occlusion; Low battery; Syringe disengaged; Syringe abnormal; Control abnormal; Internal malfunction.

Electrical safety: Complies with the stipulation of GB9706.1-1995, EN60601-1 and UL60601-1

Electromagnetic compatibility: Complies with the stipulation of IEC60601-1-2(1993 edition) EN60601-2-24

Applicable syringe: Syringes meeting national standard5ml, 10ml, 20ml, 30ml, 50ml

Feasible syringe rate range:

5ml syringe: 0.1~100ml/h 10ml syringe: 0.1~200ml/h

20ml syringe: 0.1~400ml/h 30ml syringe: 0.1~600ml/h

50ml syringe: 0.1~1500ml/h

Battery: Rechargeable lithium polymer battery, 7.4V, 1600mA

Bolus rate:

5ml: 100ml/h 10ml: 200ml/h

20ml: 400ml/h 30ml: 600ml/h

50ml: 1500ml/h

Occlusion value: 400mmHg~900mmHg

Selectable mode: Rate mode, Time mode, Body weight mode

Time Mode Volume limit: 0.1~999.9ml

Body Weight Mode: Selectable unit: Ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min

Drug limit: 0.1~9999.9(mg/ug)

Solution limit: 0.1~999.9ml

Weight: 01~300.0kg

KVO rate: 0.1ml/. 0ml/h(selectable)

Operating conditions: Environment temperature 5~45º C, air pressure 70~106kPa, relative humidity 30%~90%

Storage: Environment temperature -15~50º C, air pressure 70~106kPa, relative humidity 30%~90%

Other Information

CE Mark 0197
ISO 31485:2003